Type : Cartridge Voltage Rating : 250 V Current Rating : 1.5 A Resistance : 0.11 Ohm Interrupt Rating : 100 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1-1/4 In
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 30 Number Of Poles : 60 Number Of Circuits : 60 Breaker/Load Center Type : Plug-On Neutral Interrupt Rating : 22 KA Cable Size : 4 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Cover/Lid Type : Flush Enclosure Type : NEMA 1 Mounting Type : Flush, Surface Includes : PK15GTAL Ground Bar, Combination Flush/Surface Cover
Type : Mini Voltage Rating : 120 V Current Rating : 15 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Actuator Type : Quick-Make, Quick-Break Trip Type : Fixed Trip Sensitivity : 20.25 A Wire Size : 14 To 10, 14 To 8 AWG Terminal Type : Clamp Mounting Type : Plug Color : Black Dimensions : 1 In W X 2.98 In D X 3.13 In H Operating Temperature : 104 Deg F
Voltage Rating : 120/240 V Current Rating : 100 A Number Of Phases : 1 Number Of Spaces : 8 Number Of Circuits : 16 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KA Cable Size : #8 To 1 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Cover/Lid Type : Surface Enclosure Type : NEMA 3R Mounting Type : Plug Finish : Baked Enamel Color : Gray
Type : Cartridge Voltage Rating : 250 V Current Rating : 1 A Resistance : 0.19 Ohm Interrupt Rating : 35 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1-1/4 In
Voltage Rating : 120/240 V Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 4 Number Of Poles : 8 Number Of Circuits : 8 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KAIC Cable Size : 14 To 1/0 AWG Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Flush
Voltage Rating : 120/240 V Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 4 Number Of Poles : 8 Number Of Circuits : 8 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KA Cable Size : 14 To 1/0 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Surface Material : Metal
Type : Interchangeable, Type QP Voltage Rating : 120/240 V Current Rating : 60 A Operating Frequency : 50/60 Hz Number Of Poles : 2 Interrupt Rating : 10 KA Terminal Type : Screw Clamp Mounting Type : Plug
Type : Cartridge Voltage Rating : 250 V Current Rating : 500 MA Resistance : 0.45 Ohm Interrupt Rating : 35 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 5 Mm Length : 20 Mm
Type : Type NA Voltage Rating : 120 V Current Rating : 30 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Trip Type : Standard Wire Size : 14 To 4 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.36 In L X 1 In W X 2.55 H Suitable For : Federal Pacific Electric Load Centers
Type : Cartridge Voltage Rating : 250 V Current Rating : 4 A Resistance : 0.02 Ohm Interrupt Rating : 1500 A Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Ceramic Diameter : 5 Mm Length : 20 Mm
Type : Type THQP Voltage Rating : 120/240 V Current Rating : 40 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Frame Type : Q-Line Actuator Type : Toggle Trip Type : Non-Interchangeable Wire Size : 8 To 4 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.28 In L X 0.5 In W X 2.58 In H Operating Temperature : 60 To 75 Deg C Suitable For : Reverse Feed
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 40 Number Of Circuits : 80 Breaker/Load Center Type : Main Breaker Interrupt Rating : 25 KA Cable Size : #6 To 2/0 AWG Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Plug Material : Metal Includes : Breakers Included
Type : Cartridge Voltage Rating : 250 V Current Rating : 6 A Resistance : 0.02 Ohm Interrupt Rating : 200 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1-1/4 In
Type : Fusible Voltage Rating : 120/240 V Current Rating : 30 A Contact Configuration : DPST Number Of Poles : 2 Short Circuit Rating : 10 KA Terminal Type : Lug Number Of Wires : 3 Mounting Type : Surface NEMA Rating : NEMA 1 Length : 9-1/4 In Width : 6-3/4 In Includes : (2) Blades And Fuse Holders, (1) Solid Neutral
Type : Mini, Type CH Voltage Rating : 120/240 V Current Rating : 30 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Instantaneous Wire Size : 14 To 10, 14 To 8 AWG Number Of Spaces : 2 Mounting Type : Plug Dimensions : 3 In L X 3/4 In W X 3 In H Operating Temperature : 60 To 75 Deg C Suitable For : Type CH Load Centers
Type : Mini Voltage Rating : 120/240 VAC, 48 VDC Current Rating : 50 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 5, 10 KA Trip Type : Fixed Wire Size : 8 To 2 AWG Terminal Type : Lug Number Of Spaces : 1 Mounting Type : Plug Dimensions : 0.75 In W X 2.91 In D X 3.12 In H Operating Temperature : 104 Deg F
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 32 Number Of Poles : 2 Number Of Circuits : 40 Breaker/Load Center Type : Main Breaker Interrupt Rating : 22 KAIC Wiring Configuration : 3-Wire Bus Bar Material : Copper Enclosure Type : NEMA 1 Color : Gray
Type : Cartridge, Slow Blow Voltage Rating : 250 V Current Rating : 1 A Resistance : 0.007 Ohm Interrupt Rating : 35 A Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 5 Mm Length : 20 Mm
Voltage Rating : 250 VAC, 125 VDC Current Rating : 25 A Interrupt Rating : 20, 200 KA Fuse Type : Low Voltage, Time Delay Fuse Group : H Element Type : Dual Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Holder Body Material : Fiberglass Diameter : 9/16 In Length : 2 In
Type : Air Conditioning, Fused Voltage Rating : 120/240 V Current Rating : 30 A Number Of Phases : 1 HP Rating : 3 Hp Number Of Poles : 2 Mounting Type : Surface NEMA Rating : NEMA 3R Enclosure Material : Steel Length : 2-1/8 In Width : 5 In Height : 7-1/4 In
Voltage Rating : 240 V Current Rating : 125 A Number Of Spaces : 20 Number Of Poles : 1 Number Of Circuits : 40 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KAIC Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Plug Material : Metal Includes : Cover
Type : Twin, Type UBIZ Voltage Rating : 120/240 V Current Rating : 15/15 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Trip Type : Standard Wire Size : 14 To 8 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 4.81 In L X 0.75 W X 2.53 H Suitable For : Zinsco R3815 Series Load Centers