Type : Type UBIP Voltage Rating : 120/240 V Current Rating : 40 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Wire Size : 14 To 3 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.95 In L X 1.5 In W X 2.6 In H Suitable For : Pushmatic And Bulldog Load Centers
Type : Twin, Single Pole,Type QP Voltage Rating : 120/240 V Current Rating : 15/15 A Operating Frequency : 50/60 Hz Number Of Poles : 2 Interrupt Rating : 10 KA Mounting Type : Plug
Voltage Rating : 120 V Current Rating : 50 A Wattage Rating : 12,500 W Number Of Poles : 2 Number Of Phases : 1 Number Of Circuits : 15 Mounting Type : Surface Finish : Powder-Coated Dimensions : 11 In H X 11-3/4 In W X 4-1/2 In D Includes : (1) 20 A Two Pole Circuit Breaker, (2) 20 A 1-Pole Circuit Breakers, (6) 15 A 1-Pole Circuit Breakers
Type : Duplex, Type DNPL Voltage Rating : 120 VAC Current Rating : 15 A Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Long Time, Instantaneous, Independent Wire Size : 14 To 4 AWG Terminal Type : Plug-In Dimensions : 3 In L X 1 In W X 3 In H Suitable For : CPM, CPL, CBRPM, CBRPL Load Center
Voltage Rating : 240 V Current Rating : 125 A Number Of Spaces : 20 Number Of Poles : 1 Number Of Circuits : 40 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KAIC Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Plug Material : Metal Includes : Cover
Voltage Rating : 120/240 V Current Rating : 30 A Wattage Rating : 7500 W Number Of Poles : 15 Number Of Phases : 1 Number Of Circuits : 10 Wire Size : 10 AWG Mounting Type : Surface Dimensions : 11 In H X 11-3/4 In W X 4-1/2 In D Includes : 310C Ten-circuit Prewired Transfer Switch, PC3010 Power Cord (10 Ft, 10 AWG, L14-30 Ends) And The PB30 Outdoor Painted Steel Power Inlet Box (L14-30 Inlet)
Type : Type BQL Voltage Rating : 120/240 VAC Current Rating : 60 A Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Long Time, Instantaneous, Standard Wire Size : 8 To 2/0 AWG Terminal Type : Bolt-On Dimensions : 5 In L X 3 In W X 2 In H Suitable For : Commander QL/QM And Cutler-Hammer QM/QL Panels Includes : Captive Line Screw
Type : GFCI, Type BR Voltage Rating : 120 VAC Current Rating : 20 A Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Center, Long Time, Instantaneous Trip Sensitivity : 5 MA Wire Size : 14 To 8 AWG Terminal Type : Plug-In Dimensions : 4 In L X 3-1/2 In W X 1 In H Suitable For : CPM, CPL, CBRPM, CBRPL Load Center
Voltage Rating : 120/240 VAC Current Rating : 100 A Number Of Phases : 1 Number Of Spaces : 30 Number Of Circuits : 60 Breaker/Load Center Type : Combination, Plug-In Main Breaker, Type BR Interrupt Rating : 25 KA Cable Size : 8 To 1/0 AWG Wiring Configuration : 3-Wire Number Of Circuit Breakers : 13 Cover/Lid Type : Flush, Surface Enclosure Type : NEMA 1 Color : White Includes : (10) BR115, (1) BR215, (1) BR230, (1) BR240 Breakers
Voltage Rating : 125 To 250 V Current Rating : 20 A Number Of Phases : 1 Wire Configuration : 4-Wire Enclosure Type : NEMA 3R Finish : Powder-Coated Color : Gray
Voltage Rating : 125 To 250 V Current Rating : 30 A Number Of Phases : 1 Wire Configuration : 4-Wire Enclosure Type : NEMA 3R Material : Aluminum Finish : Powder-Coated Color : Gray
Type : Type UBIZ Voltage Rating : 120/240 V Current Rating : 100 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Wire Size : 14 To 2 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 4.9 In L X 1.5 In W X 2.75 In H Suitable For : Zinsco QCAL100 Series Load Centers
Type : Mini, Type BR Voltage Rating : 120/240 V Current Rating : 100 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 42 KA Actuator Type : Quick-Make, Quick-Break Wire Size : 4 - 1/0 AWG Mounting Type : Plug Dimensions : 6 In L X 4 In W X 2-1/4 In H Operating Temperature : 60 To 75 Deg C Suitable For : Protecting The Wires In Home From Overheating And Fault Currents
Type : Type UBIP Voltage Rating : 120/240 V Current Rating : 30 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Trip Type : Fixed Wire Size : 14 To 4 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 1.65 In L X 1.5 In W X 3.5 In H Suitable For : Pushmatic And Bulldog Load Centers
Type : Interchangeable, Type QP Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Poles : 1 Interrupt Rating : 10 KA Mounting Type : Plug
Type : Interchangeable, Type QP Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Poles : 2 Interrupt Rating : 10 KA Mounting Type : Plug
Type : Type UBIP Voltage Rating : 120/240 V Current Rating : 15 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Wire Size : 14 To 6 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 1.86 In L X 1.5 In W X 2.6 In H Suitable For : Pushmatic And Bulldog Load Centers
Type : Type UBIP Voltage Rating : 120/240 V Current Rating : 30 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Wire Size : 14 To 6 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.95 In L X 1.5 In W X 2.6 In H Suitable For : Pushmatic And Bulldog Load Centers
Type : Mini Voltage Rating : 120/240 VAC, 48 VDC Current Rating : 15 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 5, 10 KA Trip Type : Fixed Wire Size : 14 To 18 AWG Terminal Type : Pressure Contact Number Of Spaces : 1 Mounting Type : Flush Dimensions : 0.75 In W X 2.91 In D X 3 In H Operating Temperature : 104 Deg F
Voltage Rating : 120/240 VAC Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 12 Number Of Poles : 24 Number Of Circuits : 24 Breaker/Load Center Type : Main Lug, Plug-On Neutral, Type BR Interrupt Rating : 10 KAIC Cable Size : #6 To 2/0 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Flush, Surface Material : Metal Includes : Cover
Voltage Rating : 120/240 VAC Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 42 Number Of Poles : 84 Number Of Circuits : 48 Breaker/Load Center Type : Main Breaker, Plug-On Neutral, Type CH Bus Bar Material : Copper Enclosure Type : NEMA 1