GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
General Electric
  • GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    $17.99 Each

    Loading Purchase Count

    Details

    Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 Cu or 12-8 Al AWG wire, 35 to 60 A 8-3 Cu or 8-2 Al AWG wire, 70 to 100 A 6-1/0 Cu or 4-1/0 Al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).

    Specs
    Id 231015
    SKU 6122113
    PartNo THQL2160
    UPC 783164048483
    Country of OriginMade in USA USA
    Type Type THQL
    Voltage Rating 120/240 V
    Current Rating 60 A
    Operating Frequency 50/60 Hz
    Number Of Phases 1
    Number Of Poles 2
    Interrupt Rating 10 KA
    Frame Type Q-Line
    Actuator Type Quick-Make, Quick-Break
    Trip Type Non-Interchangeable
    Trip Sensitivity 600 A
    Wire Size 8 To 3, 8 To 2 AWG
    Terminal Type Lug
    Mounting Type Plug
    Dimensions 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature 60 To 75 Deg C
    Suitable For Reverse Feed
    CID 9
    Documents
    You Might Also Like
    General ElectricGE THQP150 Portable Feeder Circuit Breaker, Type SEOOW, 50 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    GE THQP150 Portable Feeder Circuit Breaker, Type SEOOW, 50 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    $9.39Each
    Dimensions: 3.28 In L X 0.5 In W X 2.58 In H
    Type
    Type SEOOW
    Voltage Rating
    120/240 V
    Current Rating
    50 A
    Operating Frequency
    50/60 Hz
    Number Of Phases
    1
    Number Of Poles
    1
    Interrupt Rating
    10 KA
    Frame Type
    Q-Line
    Actuator Type
    Toggle
    Trip Type
    Non-Interchangeable
    Wire Size
    10 AWG
    Terminal Type
    Lug
    Mounting Type
    Plug
    Dimensions
    3.28 In L X 0.5 In W X 2.58 In H
    Operating Temperature
    -50 To 105 Deg C
    Suitable For
    Reverse Feed
    General ElectricGE THQL1140 Feeder Circuit Breaker, Type THQL, 40 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    GE THQL1140 Feeder Circuit Breaker, Type THQL, 40 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    $9.39Each
    Dimensions: 3.28 In L X 1 In W X 2.38 In H
    Type
    Type THQL
    Voltage Rating
    120/240 V
    Current Rating
    40 A
    Operating Frequency
    50/60 Hz
    Number Of Phases
    1
    Number Of Poles
    1
    Interrupt Rating
    10 KA
    Frame Type
    Q-Line
    Trip Type
    Non-Interchangeable
    Trip Sensitivity
    400 A
    Wire Size
    8 To 3, 8 To 2 AWG
    Terminal Type
    Lug
    Mounting Type
    Plug
    Dimensions
    3.28 In L X 1 In W X 2.38 In H
    Operating Temperature
    60 To 75 Deg C
    Suitable For
    Reverse Feed