Map Pin LocationR.P. Lumber - Edwardsville, IL
GE THQL2140 Feeder Circuit Breaker, Type THQL, 40 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
General Electric
  • GE THQL2140 Feeder Circuit Breaker, Type THQL, 40 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug

    $17.99 Each

    Loading Purchase Count

    Details

    Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 Cu or 12-8 Al AWG wire, 35 to 60 A 8-3 Cu or 8-2 Al AWG wire, 70 to 100 A 6-1/0 Cu or 4-1/0 Al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).

    Specs
    Id 167491
    SKU 6122071
    PartNo THQL2140
    UPC 783164012934
    Country of OriginMade in USA USA
    Type Type THQL
    Voltage Rating 120/240 V
    Current Rating 40 A
    Operating Frequency 50/60 Hz
    Number Of Phases 1
    Number Of Poles 2
    Interrupt Rating 10 KA
    Frame Type Q-Line
    Actuator Type Quick-Make, Quick-Break
    Trip Type Non-Interchangeable
    Wire Size 8 To 3, 8 To 2 AWG
    Terminal Type Lug
    Mounting Type Plug
    Dimensions 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature 60 To 75 Deg C
    Suitable For Reverse Feed
    CID 9
    Documents
    Similar Items
    General Electric
    GE THQL2160 Feeder Circuit Breaker, Type THQL, 60 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $17.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 60 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Trip Sensitivity : 600 A
    Wire Size : 8 To 3, 8 To 2 AWG
    Terminal Type : Lug
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    General Electric
    GE THQL2120 Feeder Circuit Breaker, Type THQL, 20 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $17.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 20 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Wire Size : 14 To 8, 12 To 8 AWG
    Terminal Type : Screw Clamp
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    General Electric
    GE THQL2150 Feeder Circuit Breaker, Type THQL, 50 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $17.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 50 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Trip Sensitivity : 500 A
    Wire Size : 8 To 3, 8 To 2 AWG
    Terminal Type : Lug
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    General Electric
    GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $57.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 70 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Trip Sensitivity : 700 A
    Wire Size : 6 To 1/0, 4 To 1/0 AWG
    Terminal Type : Lug
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    General Electric
    GE THQL1140 Feeder Circuit Breaker, Type THQL, 40 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $8.59 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 40 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 1
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Trip Sensitivity : 400 A
    Wire Size : 8 To 3, 8 To 2 AWG
    Terminal Type : Lug
    Mounting Type : Plug
    Dimensions : 3.28 In L X 1 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    General Electric
    GE THQL2130 Feeder Circuit Breaker, Type THQL, 30 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $17.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 30 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Wire Size : 14 To 8, 12 To 8 AWG
    Terminal Type : Screw Clamp
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed