Voltage Rating : 120/240 VAC Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 8 Number Of Circuits : 16 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KA Cable Size : #6, #2/0 AWG Wiring Configuration : 3-Wire Number Of Circuit Breakers : 8 Bus Bar Material : Aluminum Cover/Lid Type : Flush Enclosure Type : NEMA 1 Mounting Type : Wall Material : Sheet Steel Color : White Includes : Grounding Bar
Voltage Rating : 125 To 250 V Current Rating : 20 A Number Of Phases : 1 Wire Configuration : 4-Wire Enclosure Type : NEMA 3R Finish : Powder-Coated Color : Gray
Voltage Rating : 240 V Current Rating : 200 A Number Of Circuits : 40 Mounting Type : Wall Material : Steel Includes : (1) 15 A, 1-Pole Double-Function ARC Combo And GFCI, (7) 15 A, 1-Pole ARC, (8) 15 A, 1-Pole, (2) 20 A, 1-Pole, (1) 30 A, 2-Pole, (1) 40 A, 2-Pole Breakers
Type : Mini, Quad Voltage Rating : 120/240 VAC Current Rating : 15, 50 A Number Of Phases : 1 Number Of Poles : 3 Interrupt Rating : 10 KA Trip Type : Common Wire Size : 14 To 8, 14 To 8 AWG Number Of Spaces : 2 Mounting Type : Plug Color : Black Dimensions : 3 In L X 2 In W X 3.13 In H Operating Temperature : 104 Deg F
Voltage Rating : 240 V Current Rating : 100 A Number Of Circuits : 32 Mounting Type : Wall Material : Steel Color : Gray Includes : (6) 15 A 1 Pole, (2) 20 A 1 Pole, (1) 30 A 2 Pole, (1) 40 A 2 Pole, (5) 15 A 1 Pole AFCI, (1) 15 A 1 Pole Dual Function AFCI/GFCI
Type : THQP Voltage Rating : 120/240 VAC Current Rating : 15 A Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Frame Type : Q-Line Trip Type : Non-Interchangeable Wire Size : 14 To 8, 12 To 8 AWG Terminal Type : Lug Mounting Type : Plug Color : Black Dimensions : 0.95 In W X 2.95 In D X 3.25 In H
Type : Mini Voltage Rating : 120 VAC Current Rating : 30 A Number Of Poles : 1 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Wire Size : 14 To 9 AWG Terminal Type : Screw Mounting Type : Plug Dimensions : 3 In L X 0.5 In W X 3.4 In H Operating Temperature : 40 Deg C
Type : Air Conditioning, Pullout Voltage Rating : 120/240 VAC Current Rating : 60 A Number Of Phases : 1 HP Rating : 3, 10 Hp Number Of Poles : 2 Fused : No Short Circuit Rating : 10 KA Number Of Wires : 2 NEMA Rating : NEMA 3R Enclosure Material : Steel Color : Gray Length : 8.79 In Width : 5.4 In Height : 3.76 In
Voltage Rating : 240 VAC Current Rating : 100 A Number Of Phases : 1 Number Of Poles : 1 Number Of Circuits : 8, 16 Breaker/Load Center Type : Main Lug Wiring Configuration : 3-Wire Mounting Type : Flush, Surface Material : Steel Color : Gray
Voltage Rating : 120/240 VAC Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 8 Number Of Circuits : 16 Breaker/Load Center Type : Non-Combination, Plug-In Main Lug, Type BR Cable Size : 14 To 2/0 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Cover/Lid Type : Flush, Surface Enclosure Type : NEMA 1 Color : Gray Includes : Cover
Type : Energy Efficient Voltage Rating : 600 VAC, 250 VDC Current Rating : 45 A Interrupt Rating : 20, 200 KA Element Type : Dual Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule, Holder Body Material : Fiberglass Diameter : 1-1/16 In Length : 5-1/2 In
Type : Low Voltage, Mini, Standard Voltage Rating : 240 VAC Current Rating : 30 A Operating Frequency : 60 Hz Number Of Phases : 3 Number Of Poles : 3 Interrupt Rating : 10 KA Frame Type : QP, MP Actuator Type : Toggle Trip Type : Common Wire Size : 14 To 8 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3 In H X 3 In W X 3 In D Operating Temperature : 40 Deg C Suitable For : Siemens EQ Load Center
Type : Energy Efficient Voltage Rating : 600 VAC, 250 VDC Current Rating : 50 A Interrupt Rating : 20, 200 KA Element Type : Dual Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule, Holder Body Material : Fiberglass Diameter : 1-1/16 In Length : 5-1/2 In
Type : Cartridge Voltage Rating : 250 V Current Rating : 5 A Resistance : 0.02 Ohm Interrupt Rating : 200 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1-1/4 In
Type : Interchangeable, Type QP Voltage Rating : 120/240 V Current Rating : 60 A Operating Frequency : 50/60 Hz Number Of Poles : 2 Interrupt Rating : 10 KA Terminal Type : Screw Clamp Mounting Type : Plug
Voltage Rating : 120/240 VAC Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 40 Number Of Poles : 80 Number Of Circuits : 40 Breaker/Load Center Type : Main Breaker, Plug-On Neutral, Type BR Interrupt Rating : 25 KAIC Cable Size : #2 To 300 Kcmil Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Flush, Surface Material : Metal Includes : Cover
Type : Mini Voltage Rating : 240 VAC Current Rating : 50 A Operating Frequency : 60 Hz Number Of Phases : 3 Number Of Poles : 3 Interrupt Rating : 10 KA Frame Type : QP Actuator Type : Toggle Trip Type : Common Wire Size : 8 To 4, 8 To 6 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 4 In H X 6 In W X 7 In D Operating Temperature : 40 Deg C Suitable For : Siemens EQ Load Center
Voltage Rating : 600 V Current Rating : 200 A Number Of Phases : 1 Number Of Jaws : 4 Wire Size : 6 AWG To 350 Kcmil Cable Entry : Underground Number Of Positions : 1 Number Of Knockouts : 6 Enclosure Type : NEMA 3R Mounting Type : Surface Material : Steel Dimensions : 13 In H X 14 In W X 5.1 In D
Type : Quad, Type BQ Voltage Rating : 120/240 V Current Rating : 20/30 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 4 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Wire Size : 14 To 4 AWG Terminal Type : Feed-Thru Number Of Spaces : 2 Mounting Type : Plug Dimensions : 3.1 In L X 0.78 In W X 2.89 In H Operating Temperature : 60 To 75 Deg C Suitable For : BR Series Load Centers
Type : Cartridge Voltage Rating : 600 V Current Rating : 15 A Interrupt Rating : 200 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule, Holder Body Material : Melamine Diameter : 13/32 In Length : 1-1/2 In
Type : Cartridge Voltage Rating : 250 V Current Rating : 4 A Resistance : 0.03 Ohm Interrupt Rating : 200 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Ceramic Color : Gray Diameter : 1/4 In Length : 1-1/4 In