Voltage Rating : 120/240 V Current Rating : 100 A Number Of Phases : 1 Number Of Spaces : 8 Number Of Circuits : 16 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KA Cable Size : #8 To 1 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Cover/Lid Type : Surface Enclosure Type : NEMA 3R Mounting Type : Plug Finish : Baked Enamel Color : Gray
Voltage Rating : 120/240 V Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 4 Number Of Poles : 8 Number Of Circuits : 8 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KAIC Cable Size : 14 To 1/0 AWG Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Flush
Type : Type THQP Voltage Rating : 120/240 V Current Rating : 40 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Frame Type : Q-Line Actuator Type : Toggle Trip Type : Non-Interchangeable Wire Size : 8 To 4 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.28 In L X 0.5 In W X 2.58 In H Operating Temperature : 60 To 75 Deg C Suitable For : Reverse Feed
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 40 Number Of Circuits : 80 Breaker/Load Center Type : Main Breaker Interrupt Rating : 25 KA Cable Size : #6 To 2/0 AWG Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Plug Material : Metal Includes : Breakers Included
Type : Mini Voltage Rating : 120/240 VAC, 48 VDC Current Rating : 50 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 5, 10 KA Trip Type : Fixed Wire Size : 8 To 2 AWG Terminal Type : Lug Number Of Spaces : 1 Mounting Type : Plug Dimensions : 0.75 In W X 2.91 In D X 3.12 In H Operating Temperature : 104 Deg F
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 32 Number Of Poles : 2 Number Of Circuits : 40 Breaker/Load Center Type : Main Breaker Interrupt Rating : 22 KAIC Wiring Configuration : 3-Wire Bus Bar Material : Copper Enclosure Type : NEMA 1 Color : Gray
Voltage Rating : 240 V Current Rating : 125 A Number Of Spaces : 20 Number Of Poles : 1 Number Of Circuits : 40 Breaker/Load Center Type : Main Lug Interrupt Rating : 10 KAIC Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Mounting Type : Plug Material : Metal Includes : Cover
Type : Twin, Type UBIZ Voltage Rating : 120/240 V Current Rating : 15/15 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Trip Type : Standard Wire Size : 14 To 8 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 4.81 In L X 0.75 W X 2.53 H Suitable For : Zinsco R3815 Series Load Centers
Voltage Rating : 120/240 V Current Rating : 60 A Number Of Phases : 1 Number Of Spaces : 2 Number Of Circuits : 4 Breaker/Load Center Type : Main Lug Interrupt Rating : 100 KA Wiring Configuration : 3-Wire Bus Bar Material : Copper Cover/Lid Type : Flush Enclosure Type : NEMA 1 Mounting Type : Surface Color : Gray
Type : GFCI, Type GFTCB Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Wire Size : 14 To 4 AWG Mounting Type : Plug Dimensions : 4-1/2 In L X 2-3/4 In W X 2 In H
Nominal Size : 2-1/2 In Material : Aluminum Number Of Mounting Holes : 4 Suitable For : Siemens And Murry Single Position Meter Sockets Includes : Screws
Voltage Rating : 250 VAC, 125 VDC Current Rating : 20 A Interrupt Rating : 20, 200 KA Fuse Type : Open, Time Delay Fuse Group : H Element Type : Dual Rejection/Non-Rejection : Rejection Terminal Type : Ferrule Body Material : Fiberglass Diameter : 9/16 In Length : 2 In
Voltage Rating : 300 V Current Rating : 135 A Number Of Phases : 1 Number Of Jaws : 4 Wire Size : 14 To 2/0 AWG Cable Entry : Overhead, Underground Number Of Positions : 1 Interrupt Rating : 10 KA Enclosure Type : NEMA 3R Mounting Type : Surface Material : Steel Dimensions : 4.9 In H X 8.7 In W X 13.3 In D
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 20 Number Of Poles : 40 Breaker/Load Center Type : Plug-On Neutral Interrupt Rating : 22 KA Cable Size : 4 AWG Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Cover/Lid Type : Flush Enclosure Type : NEMA 1 Mounting Type : Flush, Surface Includes : PK15GTAL Ground Bar, Combination Flush/Surface Cover
Voltage Rating : 120/240 V Current Rating : 100 A Number Of Phases : 1 Wire Size : 4 To 2 AWG Number Of Spaces : 32 Mounting Type : Horizontal Finish : Tin Includes : (10) 1 Pole 15 AA, (3) 2 Pole 15 AA, (1) 2 Pole 30 AA, (1) 2 Pole 40 AA QO Circuit Breaker
Voltage Rating : 120/240 V Current Rating : 30 A Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Quick-Break, Quick-Make Trip Type : Internal Common Wire Size : 12 To 10, 14 To 10 AWG Terminal Type : Bolt-On, Lug Dimensions : 3-1/2 In L X 3 In W X 1-1/2 In H
Type : Type BR Combination AFCI Voltage Rating : 120 V Current Rating : 15 A Number Of Poles : 1 Interrupt Rating : 10 KAIC Wire Size : 14 To 8/Aluminum AWG Mounting Type : Plug Dimensions : 1.1 In H X 1 In W X 2.56 In D Suitable For : Type BR Loadcenters
Type : Mini Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 1 Interrupt Rating : 10 KA Frame Type : QP Actuator Type : Magnetic, Thermal Trip Type : Fixed Wire Size : 14 To 8 AWG Terminal Type : Lug Mounting Type : Plug Dimensions : 3.6 In L X 12.8 In W X 3.5 In H Operating Temperature : 40 Deg C
Type : Fusible Voltage Rating : 240 V Current Rating : 30 A Contact Configuration : DPST Number Of Poles : 2 Short Circuit Rating : 10 KA Terminal Type : Lug Number Of Wires : 3 Mounting Type : Surface NEMA Rating : NEMA 1 Width : 5 In Height : 7.63 In