Map Pin LocationR.P. Lumber - Edwardsville, IL
Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
Eaton
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray
  • Cutler-Hammer BRP20L200G Load Center with Ground Bar, 200 A, 1 -Pole, 20 -Space, 40 -Circuit, Main Lug, Type BR Gray

$142.15 Each

Loading Purchase Count

Details

Load centers are enclosures specifically designed to house the branch circuit breakers and wiring required to distribute power to individual circuits. They contain either a main breaker when used at the service entrance point or a main lug when used as a sub-panel to add circuits to existing service. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

Specs
Id 197955
SKU 7120017
PartNo BRP20L200G
UPC 786689053277
Voltage Rating 120/240 V
Current Rating 200 A
Number Of Phases 1
Number Of Spaces 20
Number Of Poles 1
Number Of Circuits 40
Breaker/Load Center Type Main Lug, Type BR
Interrupt Rating 10 KAIC
Cable Size #1 To 300 Kcmil
Wiring Configuration 2-Wire
Bus Bar Material Aluminum
Enclosure Type NEMA 1
Color Gray
Includes Cover
CID 9
Documents
Similar Items
Eaton
Eaton BRP12L125G Load Center, 125 A, 24-Pole, 12-Space, 24-Circuit, Main Lug, Plug-On Neutral, Type BR
$72.15 Each
Voltage Rating : 120/240 VAC
Current Rating : 125 A
Number Of Phases : 1
Number Of Spaces : 12
Number Of Poles : 24
Number Of Circuits : 24
Breaker/Load Center Type : Main Lug, Plug-On Neutral, Type BR
Interrupt Rating : 10 KAIC
Cable Size : #6 To 2/0 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Aluminum
Enclosure Type : NEMA 1
Mounting Type : Flush, Surface
Material : Metal
Includes : Cover
Eaton
Cutler-Hammer BR BR612L125FDP Load Center, 125 A, 6 -Space, 12 -Circuit, Main Lug, NEMA 1 Enclosure, Light Gray Light Gray
$43.15 Each
Voltage Rating : 120/240 V
Current Rating : 125 A
Number Of Phases : 1
Number Of Spaces : 6
Number Of Circuits : 12
Breaker/Load Center Type : Main Lug
Interrupt Rating : 10 KA
Cable Size : #14 To 1 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Aluminum
Enclosure Type : NEMA 1
Mounting Type : Flush
Color : Light Gray
Eaton
Cutler-Hammer BR BR612L125SP Load Center, 125 A, 6 -Space, 12 -Circuit, Main Lug, NEMA 1 Enclosure, Light Gray Light Gray
$39.19 Each
Voltage Rating : 120/240 V
Current Rating : 125 A
Number Of Phases : 1
Number Of Spaces : 6
Number Of Circuits : 12
Breaker/Load Center Type : Main Lug
Interrupt Rating : 10 KA
Cable Size : #14 To 1 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Aluminum
Enclosure Type : NEMA 1
Mounting Type : Surface
Color : Light Gray
Eaton
Cutler-Hammer CH CH2L70SP Load Center, 70 A, 2 -Space, 4 -Circuit, Main Lug, NEMA 1 Enclosure, Surface Mounting
$25.99 Each
Voltage Rating : 120/240 V
Current Rating : 70 A
Number Of Phases : 1
Number Of Spaces : 2
Number Of Circuits : 4
Breaker/Load Center Type : Main Lug
Interrupt Rating : 10 KA
Cable Size : #14 To 2 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Copper
Enclosure Type : NEMA 1
Mounting Type : Surface
Eaton
Cutler-Hammer BR BR24L125RP Load Center, 125 A, 2 -Space, 4 -Circuit, Main Lug, NEMA 3R Enclosure, Light Gray Light Gray
$46.35 Each
Voltage Rating : 120/240 V
Current Rating : 125 A
Number Of Phases : 1
Number Of Spaces : 2
Number Of Circuits : 4
Breaker/Load Center Type : Main Lug
Interrupt Rating : 10 KA
Cable Size : #14 To 1/0 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Aluminum
Enclosure Type : NEMA 3R
Mounting Type : Surface
Color : Light Gray
Eaton
Cutler-Hammer BR BR24L70SP Load Center, 70 A, 2 -Space, 4 -Circuit, Main Lug, NEMA 1 Enclosure, Surface Mounting Light Gray
$21.99 Each
Voltage Rating : 120/240 V
Current Rating : 70 A
Number Of Phases : 1
Number Of Spaces : 2
Number Of Circuits : 4
Breaker/Load Center Type : Main Lug
Interrupt Rating : 10 KA
Cable Size : #8 To 2 AWG
Wiring Configuration : 3-Wire
Bus Bar Material : Aluminum
Enclosure Type : NEMA 1
Mounting Type : Surface
Color : Light Gray