GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
General Electric
  • GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
  • GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
  • GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
  • GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug

$63.25 Each

Loading Purchase Count

Details

Copper-to-copper connections, calibrated for optimum trip performance, heat-resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 A 14-8 Cu or 12-8 Al AWG wire, 35 to 60 A 8-3 Cu or 8-2 Al AWG wire, 70 to 100 A 6-1/0 Cu or 4-1/0 Al AWG wire. UL Listed, HACR rated. 120/240 V, 10,000 Air. 1 in per pole (2 in total).

Specs
Id 203723
SKU 6122121
PartNo THQL2170
UPC 783164099201
Country of OriginMade in USA USA
Type Type THQL
Voltage Rating 120/240 V
Current Rating 70 A
Operating Frequency 50/60 Hz
Number Of Phases 1
Number Of Poles 2
Interrupt Rating 10 KA
Frame Type Q-Line
Actuator Type Quick-Make, Quick-Break
Trip Type Non-Interchangeable
Trip Sensitivity 700 A
Wire Size 6 To 1/0, 4 To 1/0 AWG
Terminal Type Lug
Mounting Type Plug
Dimensions 3.28 In L X 2 In W X 2.38 In H
Operating Temperature 60 To 75 Deg C
Suitable For Reverse Feed
CID 9
Documents
You Might Also Like
General ElectricGE THQP150 Portable Feeder Circuit Breaker, Type SEOOW, 50 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

GE THQP150 Portable Feeder Circuit Breaker, Type SEOOW, 50 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

$9.39Each
Dimensions: 3.28 In L X 0.5 In W X 2.58 In H
Type
Type SEOOW
Voltage Rating
120/240 V
Current Rating
50 A
Operating Frequency
50/60 Hz
Number Of Phases
1
Number Of Poles
1
Interrupt Rating
10 KA
Frame Type
Q-Line
Actuator Type
Toggle
Trip Type
Non-Interchangeable
Wire Size
10 AWG
Terminal Type
Lug
Mounting Type
Plug
Dimensions
3.28 In L X 0.5 In W X 2.58 In H
Operating Temperature
-50 To 105 Deg C
Suitable For
Reverse Feed
General ElectricGE THQL1140 Feeder Circuit Breaker, Type THQL, 40 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

GE THQL1140 Feeder Circuit Breaker, Type THQL, 40 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug

$9.39Each
Dimensions: 3.28 In L X 1 In W X 2.38 In H
Type
Type THQL
Voltage Rating
120/240 V
Current Rating
40 A
Operating Frequency
50/60 Hz
Number Of Phases
1
Number Of Poles
1
Interrupt Rating
10 KA
Frame Type
Q-Line
Trip Type
Non-Interchangeable
Trip Sensitivity
400 A
Wire Size
8 To 3, 8 To 2 AWG
Terminal Type
Lug
Mounting Type
Plug
Dimensions
3.28 In L X 1 In W X 2.38 In H
Operating Temperature
60 To 75 Deg C
Suitable For
Reverse Feed