Map Pin LocationR.P. Lumber - Edwardsville, IL
Cutler-Hammer GFTCB250 Circuit Breaker, GFCI, Type GFTCB, 50 A, 2 -Pole, 120/240 V, Plug Mounting
Eaton
  • Cutler-Hammer GFTCB250 Circuit Breaker, GFCI, Type GFTCB, 50 A, 2 -Pole, 120/240 V, Plug Mounting

    $169.99 Each

    Loading Purchase Count

    Details

    GFCB main circuit breaker. BR ground fault self-test. Interrupt rating 10 kAIC. Common trip. 2-pole, requires two 1 in spaces. 120/240 V. Meets Federal Spec Classification W-C375.

    Specs
    Id 195504
    SKU 7120082
    PartNo GFTCB250
    UPC 786676025997
    Country of OriginMade in USA USA
    Type GFCI, Type GFTCB
    Voltage Rating 120/240 V
    Current Rating 50 A
    Operating Frequency 50/60 Hz
    Number Of Phases 1
    Number Of Poles 2
    Interrupt Rating 10 KA
    Wire Size 14 To 4 AWG
    Mounting Type Plug
    Dimensions 4-1/2 In L X 2-3/4 In W X 2 In H
    CID 9
    Documents
    Similar Items
    Eaton
    Cutler-Hammer BQ220240 Circuit Breaker with Rejection Tab, Quad, Type BQ, 20/40 A, 4 -Pole, 120/240 V
    $37.99 Each
    Type : Quad, Type BQ
    Voltage Rating : 120/240 V
    Current Rating : 20/40 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 4
    Interrupt Rating : 10 KA
    Actuator Type : Magnetic, Thermal
    Wire Size : 14 To 4 AWG
    Number Of Spaces : 2
    Mounting Type : Plug
    Dimensions : 3.1 In L X 1.97 In W X 2.88 In H
    Operating Temperature : 60 To 75 Deg C
    General Electric
    GE THQL2170 Feeder Circuit Breaker, Type THQL, 70 A, 2-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $57.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 70 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Trip Sensitivity : 700 A
    Wire Size : 6 To 1/0, 4 To 1/0 AWG
    Terminal Type : Lug
    Mounting Type : Plug
    Dimensions : 3.28 In L X 2 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    Eaton
    Cutler-Hammer CHF240CS Circuit Breaker with Flag, Mini, Type CHF, 40 A, 2 -Pole, 120/240 V, Common, Fixed Trip
    $29.99 Each
    Type : Mini, Type CHF
    Voltage Rating : 120/240 V
    Current Rating : 40 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Actuator Type : Magnetic, Thermal
    Trip Type : Common, Fixed
    Wire Size : 10 To 1/0 AWG
    Number Of Spaces : 2
    Mounting Type : Plug
    Dimensions : 6 In L X 4 In W X 2 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Type CH Load Centers
    General Electric
    GE THQL1130 Feeder Circuit Breaker, Type THQL, 30 A, 1-Pole, 120/240 V, Non-Interchangeable Trip, Plug
    $6.99 Each
    Type : Type THQL
    Voltage Rating : 120/240 V
    Current Rating : 30 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 1
    Interrupt Rating : 10 KA
    Frame Type : Q-Line
    Actuator Type : Quick-Make, Quick-Break
    Trip Type : Non-Interchangeable
    Wire Size : 14 To 8, 12 To 8 AWG
    Terminal Type : Screw Clamp
    Mounting Type : Plug
    Dimensions : 3.28 In L X 1 In W X 2.38 In H
    Operating Temperature : 60 To 75 Deg C
    Suitable For : Reverse Feed
    Eaton
    Cutler-Hammer BR2020 Circuit Breaker, Duplex, Type BR, 20 A, 2 -Pole, 120/240 V, Plug Mounting
    $24.99 Each
    Type : Duplex, Type BR
    Voltage Rating : 120/240 V
    Current Rating : 20 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 2
    Interrupt Rating : 10 KA
    Actuator Type : Quick-Make, Quick-Break
    Wire Size : 14 To 4 AWG
    Mounting Type : Plug
    Dimensions : 3.1 In L X 0.98 In W X 2.89 In H
    Operating Temperature : 60 To 75 Deg C
    Eaton
    Cutler-Hammer BR150 Circuit Breaker, Mini, Type BR, 50 A, 1 -Pole, 120/240 V, Plug Mounting
    $9.05 Each
    Type : Mini, Type BR
    Voltage Rating : 120/240 V
    Current Rating : 50 A
    Operating Frequency : 50/60 Hz
    Number Of Phases : 1
    Number Of Poles : 1
    Interrupt Rating : 42 KA
    Actuator Type : Quick-Make, Quick-Break
    Wire Size : 14 To 4 AWG
    Mounting Type : Plug
    Operating Temperature : 40 Deg C