Type : Type UBIZ Voltage Rating : 120/240 V Current Rating : 60 A Operating Frequency : 50/60 Hz Number Of Poles : 2 Interrupt Rating : 10 KA Trip Type : Standard Mounting Type : Plug Dimensions : 4.81 In L X 1.5 W X 2.53 H Suitable For : Zinsco QCAL60 Series Load Centers
Voltage Rating : 250 VAC, 125 VDC Current Rating : 40 A Interrupt Rating : 20, 200 KA Fuse Type : Open, Time Delay Fuse Group : K Element Type : Dual Rejection/Non-Rejection : Rejection Terminal Type : Ferrule Body Material : Fiberglass Diameter : 13/16 In Length : 3 In
Type : Cartridge Voltage Rating : 250 V Current Rating : 3 A Resistance : 0.03 Ohm Interrupt Rating : 100 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 5 Mm Length : 20 Mm
Type : Mini, Type CHF Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Common, Fixed Wire Size : 14 To 10, 14 To 8 AWG Number Of Spaces : 2 Mounting Type : Plug Dimensions : 7-1/4 In L X 4-1/2 In W X 63-1/2 In H Operating Temperature : 60 To 75 Deg C
Type : Quad, Type BQ Voltage Rating : 120/240 V Current Rating : 20 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 4 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Wire Size : 14 To 4 AWG Terminal Type : Feed-Thru Mounting Type : Plug Dimensions : 3.1 In L X 1.97 In W X 2.89 In H Operating Temperature : 60 To 75 Deg C
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 8 Number Of Jaws : 4 Number Of Circuits : 16 Interrupt Rating : 22 KA Wiring Configuration : 3-Wire Bus Bar Material : Copper Cover/Lid Type : Ring Enclosure Type : NEMA 3R Mounting Type : Surface
Type : Ringless Voltage Rating : 600 V Current Rating : 200 A Number Of Phases : 1 Number Of Jaws : 4 Feed Type : Overhead, Underground Wire Configuration : 3-Wire Cable Entry : Overhead, Underground Number Of Positions : 1 Mounting Type : Surface Material : Stainless Steel Color : Black Dimensions : 5.7 In H X 12.1 In W X 16.5 In D
Type : Type CL Voltage Rating : 120/240 V Current Rating : 40 A Operating Frequency : 50/60 Hz Number Of Phases : 1 Number Of Poles : 2 Interrupt Rating : 10 KA Actuator Type : Magnetic, Thermal Trip Type : Common Wire Size : 14 To 4 AWG Mounting Type : Plug Dimensions : 3 In L X 2 In W X 3 In H Operating Temperature : 60 To 75 Deg C Suitable For : Load Centers
Type : Cartridge Voltage Rating : 250 V Current Rating : 1.5 A Resistance : 0.06 Ohm Interrupt Rating : 100 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1 In
Type : Low Voltage Voltage Rating : 120 V Current Rating : 40 A Number Of Poles : 1 Interrupt Rating : 10 KA Frame Type : QD Mounting Type : Plug Dimensions : 1 In H X 3 In W X 3 In D Operating Temperature : 40 Deg C Suitable For : Square D QO Load Center
Type : Cartridge Voltage Rating : 600 V Current Rating : 20 A Interrupt Rating : 200 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule, Holder Body Material : Melamine Diameter : 13/32 In Length : 1-1/2 In
Type : Cartridge Voltage Rating : 125 V Current Rating : 6 A Resistance : 0.01 Ohm Interrupt Rating : 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 5 Mm Length : 20 Mm
Type : Cartridge Voltage Rating : 250 V Current Rating : 1 A Resistance : 0.23 Ohm Interrupt Rating : 1500 A Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Ceramic Diameter : 5 Mm Length : 20 Mm
Type : Cartridge Voltage Rating : 250 V Current Rating : 8 A Resistance : 0.01 Ohm Interrupt Rating : 200 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 1-1/4 In
Voltage Rating : 125 V Current Rating : 15 A Interrupt Rating : 10 KA Fuse Type : Low Voltage, Time Delay Element Type : Dual Rejection/Non-Rejection : Rejection
Voltage Rating : 120/240 VAC Current Rating : 125 A Number Of Phases : 1 Number Of Spaces : 12 Number Of Circuits : 24 Breaker/Load Center Type : Main Lug, Plug-On Neutral Interrupt Rating : 100 KA Wiring Configuration : 3-Wire Bus Bar Material : Aluminum Enclosure Type : NEMA 1 Temperature Rating : 60 To 75 Deg C Mounting Type : Flush, Surface Color : Gray Includes : (1) Factory Installed Ground Bar
Voltage Rating : 120/240 VAC Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 20 Number Of Circuits : 40 Breaker/Load Center Type : Main Breaker, Plug-On Neutral Interrupt Rating : 22 KA Wiring Configuration : 3-Wire Bus Bar Material : Copper Enclosure Type : NEMA 1 Temperature Rating : 60 To 75 Deg C Mounting Type : Flush, Surface Color : Gray Includes : (2) Factory Installed Ground Bars
Voltage Rating : 600 V Current Rating : 200 A Number Of Phases : 1 Number Of Jaws : 4 Wire Size : 6 AWG To 350 Kcmil Cable Entry : Overhead, Underground Number Of Positions : 1 Enclosure Type : NEMA 3R Mounting Type : Surface Material : Steel Dimensions : 5.8 In H X 12 In W X 16.5 In D
Type : Cartridge Voltage Rating : 600 V Current Rating : 30 A Interrupt Rating : 200 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Rejection Terminal Type : Ferrule, Holder Body Material : Melamine Diameter : 13/32 In Length : 1-1/2 In
Voltage Rating : 250 VAC, 125 VDC Current Rating : 70 A Interrupt Rating : 10, 50 KA Fuse Type : Fast Acting, Non-Current Limiting Fuse Group : H Element Type : Single Indicator Type : Non-Indicating Body Material : Melamine Diameter : 1-1/16 In Length : 5-7/8 In
Voltage Rating : 120/240 V Current Rating : 200 A Number Of Phases : 1 Number Of Spaces : 20 Number Of Poles : 40 Interrupt Rating : 10 KA Bus Bar Material : Aluminum Enclosure Type : NEMA 3R Mounting Type : Flush
Type : Cartridge Voltage Rating : 250 V Current Rating : 1.5 A Resistance : 0.07 Ohm Interrupt Rating : 100 A, 10 KA Element Type : Single Indicator Type : Non-Indicating Rejection/Non-Rejection : Non-Rejection Terminal Type : Ferrule Body Material : Glass Diameter : 1/4 In Length : 5/8 In
Voltage Rating : 250 VAC, 125 VDC Current Rating : 15 A Interrupt Rating : 50 KA Fuse Type : Cartridge Element Type : Single Rejection/Non-Rejection : Non-Rejection Body Material : Melamine Diameter : 0.56 In Length : 2 In
Type : AFCI, Dual Function, GFCI Voltage Rating : 120/240 VAC Current Rating : 20 A Number Of Phases : 1 Number Of Poles : 1 Mounting Type : Plug Dimensions : 3.3 In H X 1 In W X 3.3 In D